Sign In | Join Free | My hardware-wholesale.com
China DongGuan Q1-Test Equipment Co., Ltd. logo
DongGuan Q1-Test Equipment Co., Ltd.
Professional Supplier of Climatic Testing Equipment
Site Member

8 Years

Home > Temperature Humidity Chamber >

Forced Air Damper Three-Zone Static Thermal Shock Test Chamber Internal SUS304 Stainless Steel

DongGuan Q1-Test Equipment Co., Ltd.
Contact Now

Forced Air Damper Three-Zone Static Thermal Shock Test Chamber Internal SUS304 Stainless Steel

Brand Name : iqualitrol

Model Number : QTS3-40A

MOQ : 1 Set

Payment Terms : T/T

Supply Ability : 10 Sets per Month

Delivery Time : 30 Working Days

Packaging Details : Plywood Box

Volume : Internal 56L, 40 x 35 x 40cm

Temperature : Range -20℃ ~ +150℃

Heating : Rate RT ~ +200℃, within 35min

Cooling : Rate -10℃ ~ -70℃, within 85min

Temp. : Uniformity Less than ±2℃

Transition time : <10 seconds

Contact Now

Forced Air Damper Three-zone Static Thermal Shock Test Chamber in SUS304 stainless steel

Brief Introduction:

Q1-Test thermal shock test chamber is used to test products in alternating extremes of high and low temperatures in order to observe changes in product characteristics and failure occurrence.

QTS3 series air-to-air thermal shock chambers circulate cold, hot, or ambient air as needed. The conditioned air is pre-cooled or pre-heated beyond the set point, allowing quicker recovery of the desired condition after transfer, call Mr. Andy Dai 0086-13450058229 or email sales@q1-test.com ask for price.

QTS3-40 Features:
Automatically setting of pro-cooled and pre-heated air.

Testing samples don’t move, cable port is available for power on testing

Powerful interactive touch screen controller, easy operation and setting

High accurate temperature recovery with PID auto tuning

Auto defrost function

Testing Standards:

MIL-STD-883E Method 1011.9 Thermal Shock

MIL-STD-202G Method 107G thermal Shock

JIS C 0025 Change of temperature

IEC 61300-2-47 Tests-Thermal Shocks

JEDEC JESD47E

JESD22-A104C Temperature cycling

GB/T 2423.22-2012 Test N: Change of temperature

SJ/T10186-91Y73

Model Selection:

Model

Interior dimensions

(W ×H × D)

Interior Volume

Exterior dimensions

(W ×H × D)

Specimen loading weight
QTS3-40A/B/C

400 ×350× 400mm

15.7”×13.8”×15.7”

56L

1450× 1950 ×1600mm

57.1” ×76.8” ×63.0”

2.5Kg
QTS3-50A/B/C

500 ×400× 400mm

19.7”×15.7”×15.7”

80L

1550× 2050 ×1600mm

61.0” ×80.7” ×63.0”

5.0Kg
QTS3-60A/B/C

600 ×500× 500mm

23.6”×19.7”×19.7”

150L

1650× 2150 ×1800mm

64.9” ×84.7” ×70.9”

7.5Kg
QTS3-75A/B/C

750 ×600× 500mm

29.5”×23.6”×19.7”

225L

1850× 2250 ×1800mm

72.8” ×88.6” ×70.9”

7.5Kg

Technical Specifications:

Structure Pre-cooling Zone, Pre-heating Zone, Testing Zone (Selectable 2-Zone or 3-Zone Test for stationary object test)
Damper Device Forced Air Damper
Interior Material SUS#304 Stainless Steel
Exterior Material stainless steel with environmentally baking paint
Testing Shelves Stainless Steel Plate
Refrigeration Cascade Refrigeration System
Cooling Method Water/Air Cooling
Ambient Temperature 5℃~30℃
Pre-heating Temperature 80℃~200℃
Pre-cooling Temperature -40℃ (-60℃/-75℃)~-10℃
High Temp. Shocking 60℃~150℃
Low Temp. Shocking

A=―35℃~0℃

B=―55℃~10℃

C=―65℃~10℃

Temp. Uniformity Less than ±2℃
Transition time <10 seconds
High Temp. Recovery time RT℃~150℃/5min
Low Temp. Recovery time RT℃~-75℃/5min
Pre-heating Time 40min (30min for 56L)
Pre-cooling Time 80min (60min for 56L)
Controller Powerful interactive LCD touch screen controller
Setting Range

Temperature: -200℃~300℃

Time: 0H1m~9999H59m

Cycle: 1~9999cycle

Resolution

Temperature: 0.01℃

Time: 1min

Control Method PID+SSR
Power supply AC380V/50Hz/3P
Accessories

Viewing Window, Cable Port, Chamber Illumination,

LCD touch screen controller, Power cable

Security System Overheat Protector, Compressor overload protector, Controller protector, Motor overload protector
Note:

1. Ambient temperature of +23℃ and a cooling water temperature of +25℃

2. During pre-heating, prevention for temperature heat-up may be worked

3. Performance shown above conforms to IEC61300-2-47

4. Temperature heat-up/pull-down time is applicable only during independent chamber operation


Product Tags:

shock test machine

      

climatic test chamber

      
China Forced Air Damper Three-Zone Static Thermal Shock Test Chamber Internal SUS304 Stainless Steel wholesale

Forced Air Damper Three-Zone Static Thermal Shock Test Chamber Internal SUS304 Stainless Steel Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: DongGuan Q1-Test Equipment Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)